TM 55-1520-240-23-1
1-51
SINGLE POINT REFUELING
(Continued)
1-51
21.
To add fuel to left forward fuel tank.
a.
Set FUEL QTY SEL switch (8) to L FWD.
b.
Set FUEL CELL SHUTOFF VALVE TEST LH
REFUEL FWD switch (10) to FLOW.
c.
Set FUEL CELL SHUTOFF VALVE TEST LH
REFUEL FWD switch (10) to PRI OFF when
pointer (9) indicates fuel level desired.
22.
To add fuel to aft right fuel tank.
a.
Set FUEL QTY SEL switch (8) to R AFT.
b.
Set FUEL CELL SHUTOFF VALVE TEST RH
REFUEL AFT switch (10) to FLOW.
c.
Set FUEL CELL SHUTOFF VALVE TEST RH
REFUEL AFT switch (10) to PRI OFF when
pointer (9) indicates fuel level desired.
23.
To add fuel to right main fuel tank.
a.
Set FUEL QTY SEL switch (8) to R MAIN.
b.
Set FUEL CELL SHUTOFF VALVE TEST RH
REFUEL MAIN switch (10) to FLOW.
c.
Set FUEL CELL SHUTOFF VALVE TEST RH
REFUEL MAIN switch (10) to PRI OFF when
pointer (9) indicates fuel level desired.
24.
To add fuel to right forward fuel tank.
a.
Set FUEL QTY SEL switch (8) to R FWD.
b.
Set FUEL CELL SHUTOFF VALVE TEST RH
REFUEL FWD switch (10) to FLOW.
c.
Set FUEL CELL SHUTOFF VALVE TEST RH
REFUEL FWD switch (10) to PRI OFF when
pointer (9) indicates fuel level desired.
1-197