TM  55-1520-240-23-7 9-34 INSTALL APU  GENERATOR (Continued) 9-34 1. Apply  a  light  coating  of  grease  (E190)  to generator shaft splines  (1). APU generator is heavy and can  injure personnel if  it drops.  Generator must be  held  firmly  and  moved  carefully to  prevent  injury. 2. Install  generator (2) over studs (3) with  nuts  (5), large  terminal board  (4) down.  Rotate  generator clockwise.   Tighten  nuts (5). 3. Position  air  inlet (6) on  generator (2) and  install five  screws  (7). NOTE Top  screw in  air inlet is  omitted. 4. Lockwire  (E231)  screws  (7). 5. Install  screen  (8) and  clamp  (9). 9-109