TM 55-1520-240-23-7
9-13
INSTALL REVERSE CURRENT CUTOUT (RCCO) RELAY
(Continued)
9-13
NOTE
Procedure is same for installation of
reverse current cutout (RCCO) relay
in No. 1 or No. 2 power distribution
panel. Installation of RCCO relay
in No. 2 power distribution panel is
shown here.
1.
Position RCCO relay (1). Install four bolts (2) and
washers (3).
2.
Position bar (4) on terminal (5) and tighten nut
(6).
3.
Install washer (7) and nut (8) on terminal (5).
4.
Remove tape. Connect seven wires (9) to four
terminals (10) by installing four washers (11) and
nuts (12). Remove tags.
INSPECT
5.
Close panel (13). Tighten six fasteners (14).
FOLLOW-ON MAINTENANCE:
Perform operational check of dc power system (TM
55-1520-240-T).
END OF TASK
9-49