INSTALL DC POWER RECEPTACLE
REMOVE  DC CABIN  UTILITY  RECEPTACLE

TM-55-1520-240-23-7 CH-47D Heilcopter Manual
Page Navigation
  380    381    382    383    384  385  386    387    388    389    390  
TM  55-1520-240-23-7 9-5 INSTALL  DC  POWER  RECEPTACLE (Continued) 9-5 5. Install  two  screws (10)  in  receptacle  (3). Sealant  (E336)  can  irritate  skin  and cause  burns.  Avoid  contact  with  skin, eyes,  and  clothing.  In  case  of  contact, immediately  flush  skin  or  eyes  with water  for  at  least  15 minutes.   Get medical  attention  for  eyes. 6. Apply  sealant  to  screws  (10)  and  edge  of receptacle  (3).  Use  sealant  (E336).  Wear  gloves (E186). INSPECT FOLLOW-ON  MAINTENANCE: Perform  operational  check (TM 55-1520-240-T). Close  EXT  PWR  DC-AC  access  cover  (Task 2-2). END  OF  TASK 9-28