DIRECT CURRENT (DC) POWER  DISTRIBUTION SYSTEM (Continued) - TM-55-1520-240-23-7_397
DIRECT CURRENT (DC) POWER  DISTRIBUTION SYSTEM (Continued) - TM-55-1520-240-23-7_399

TM-55-1520-240-23-7 CH-47D Heilcopter Manual
Page Navigation
  366    367    368    369    370  371  372    373    374    375    376  
TM  55-1520-240-23-7 9-1 DIRECT CURRENT (DC) POWER  DISTRIBUTION SYSTEM (Continued) 9-1 If  the  detection  circuit  determines that TR output  is  not acceptable, no  output from  the  TR  is applied  to  the  APP RCCO,  the  internal  main  contactor is  not  energized, isolating  the  TR  from  the  aircraft  dc bus.   When  this happens,  TR  failure  relay  161K5  (No.  1) or 161K6  (No. 2) is  de-energized,  lighting  the  relevant  RECT  OFF  light on  the  master  caution  panel  and  energizing  dc  bus tie relay  161K8.  Energizer  161K8  connects the  No.  1  and No.   2  dc  busses,  allowing  both  to  be  powered  by the operating  TR. 9-14