TM 55-1520-240-23-7
8-112
INSTALL MISCELLANEOUS LIGHTS ON CENTER INSTRUMENT PANEL
(Continued)
8-112
4.
Position socket (8) in panel (1). Install nut (9)
and washer (10).
5.
Splice wires (11) to socket (8) (TM
55-1500-323-25).
6.
Remove tag and position light base (12) in panel
(1). Install nut (13) and washer (14) on light base.
7.
Install lamp (15) in lens (16). Install lens in light
base (12).
8.
Install each light fixture (17) by threading wire
(18) through hole in panel (1). Install two
screws (19). Splice wire behind panel (TM
55-1500-323-25).
FOLLOW-ON MAINTENANCE:
Perform operational check of affected systems (TM
55-1520-240-T).
END OF TASK
8-366