TM 55-1520-240-23-7
8-110
INSTALL MISCELLANEOUS LIGHTS ON PILOTS OR COPILOTS INSTRUMENT
PANEL (Continued)
8-110
CAUTION
Do not over-torque nut (24). Tighten
nut until snug only.
NOTE
Light must be positioned as shown.
Lights at turn and slip indicators
require non-magnetic washers. If
removed, NAS spacers must be used.
10.
Position postlight (22) in panel (1). Install washer
(23), collar (23.1), and nut (24).
11.
(Without 17 ), reach behind panel (1) and
connect wire (25) to postlight (22).
12.
(With 17 ), reach behind panel (1) and screw
wire (25) into postlight (22).
INSPECT
13.
Install light fixture (26) by threading wire (27)
through hole in panel (1). Install two screws (28).
Splice wire behind panel (TM 55-1500-323-25).
FOLLOW-ON MAINTENANCE:
Perform operational check of affected systems (TM
55-1520-240-T).
END OF TASK
Change 1
8-361