TM 55-1520-240-23-6
7-218.2
INSTALL UTILITY HYDRAULIC SYSTEM ACCUMULATOR
(Continued)
7-218.2
5.
Working from pylon right access door, position
accumulator (1) in two clamps (13), fitting (5)
outboard, and valve (14) upright.
6.
Close clamps (13) and install two nuts (15). Do
not tighten nuts at this time.
7.
Connect valve (16) to tee (10) of accumulator (1).
8.
Connect tube (17) to tee (10).
9.
Tighten nuts (15).
10.
Tighten nut (12).
11.
Lockwire clamps (13). Use lockwire (E231).
12.
Lockwire nut (18) to accumulator (1). Use
lockwire (E231).
INSPECT
FOLLOW-ON MAINTENANCE:
Service utility hydraulic system and accumulator
(Task 1-59 and 1-68).
Bleed hydraulic system (refer to Index).
Perform operational check (TM 55-1520-240-T).
Close pylon right access door (Task 2-2).
END OF TASK
7-834