TM  55-1520-240-23-6
7-10
FLUSHING  FLIGHT CONTROL HYDRAULIC  SYSTEM  (PRESSURE  LINES)
7-10
INITIAL  SETUP
Applicable  Configurations:
All
Tools:
Hydraulics  Repairers  Tool  Kit,   NSN
5180-00-323-4891
Containers
Hydraulic  Test  Stand
Filter Assembly  Kit  ADHT6814-M9716M
Materials:
Hydraulic  Fluid  (E199)
Cloths  (E120)
Gloves  (E184.1)
Parts:
Hoses
Fittings
Unions
Personnel  Required:
Aircraft  Pneudraulics  Repairer
Inspector
Equipment  Condition:
Flight  Control  System  Prepared  for Flushing  (Task
7-9)
General  Safety Instructions:
Hydraulic fluid  (E199)  is toxic.  It  can
irritate  skin  and  cause  burns.   Avoid
inhaling.   Use  only  with  adequate
ventilation.  Avoid  contact  with  skin,
eyes,  or  clothing.  In  case  of  contact,
immediately  flush  skin  or eyes  with
water for  at  least  15 minutes.   Get
medical  attention  for eyes.
Hydraulic fluid  ejected  under pressure
can  cause  injury  to  personnel.
Hydraulic fluid  sprayed  into  the  air  is
a  fire  hazard.
7-64