TM 55-1520-240-23-6
7-156
REMOVE PRESSURE CONTROL MODULE FILTER
(Continued)
7-156
NOTE
If diaphram must be removed, refer to
Task 7-349.
1.
Remove lockwire and disconnect connector (1)
from indicator (2).
2.
Remove lockwire from filter bowl (3). Remove
bowl from filter port (4). Use container and cloths
(E135) for spilled fluid. Use gloves (E186).
2.1.
Remove retainer (4.1) and packings (4.2 and
4.3).
3.
Remove filter element (5) from bowl (3). Discard
filter.
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-681