TM 55-1520-240-23-6
7-125
REMOVE AFT PIVOTING SERVOCYLINDER
(Continued)
7-125
1.
Tag and disconnect two hoses (1) from tees (2).
Use container and cloths (E135) for spilled fluid.
Wear gloves(E184.1).
2.
Tag and disconnect two hoses (3) from
servocylinder (4). Use container and cloths
(E135) for spilled fluid. Wear gloves (E184.1).
Positive retention bolts are installed in
the upper controls. They have a pawl
which prevents nut or bolt removal
unless the pawl is depressed.
3.
Remove cotter pin (5), nut (6), washer (7), and
bolt (8) from lugs (9).
7-559