TM 55-1520-240-23-6
7-126
REMOVE FORWARD SWIVELING SERVOCYLINDER
(Continued)
7-126
1.
Have helper, in passageway, tag and disconnect
two hoses (1) from tees (2). Use container and
cloths (E135) for spilled fluid. Use gloves (E186).
2.
From work platform, remove screw (3), washer
(4), and nut (5) from clamp (6).
3.
Tag and disconnect two hoses (7) from
servocylinder (8). Use container and cloths
(E135) for spilled fluid.
4.
Remove cotter pin (9), nut (10), washer (11), and
bolt (12) from lugs (13).
7-563