TM 55-1520-240-23-6
7-329
FLUSH UTILITY PUMP AND APU RETURN TUBING
(Continued)
7-329
5.
Working right of pylon, disconnect two tubes (11
and 12) from utility reservoir/cooler (13).
6.
Connect hose (14) to tubes (11 and 12).
7.
Disconnect tee fitting (15) from accumulator (16).
8.
Install plug (17) in fitting (15).
7-1209