  59    60    61    62    63  64  65    66    67    68    69  
TM 55-1520-240-23-5 6-20 ALIGN FORWARD DRIVE SHAFTING     (Continued) 6-20 7. Remove nuts (8), washers (6 and 7), and bolts (5) from both ends of shaft (3). Remove shaft. 8. Remove adapter assembly (1). WARNING Dry cleaning solvent (E162) is flammable and toxic.  It can irritate skin and cause burns.  Use only in well-ventilated area, away from heat and open flame.  In case of contact, immediately flush skin or eyes with plenty of water for at least 15 minutes. Get medical attention for eyes. 8.1. Clean splines of adapter assembly (1), retainer (16), and output shaft (2).  Use dry cleaning solvent (E162) and cloths (E120).  Wear gloves (E186). 8.2. Pack splines of adapter assembly (1), retainer (16), and output shaft (2) with grease (E190.1). Wipe off excess grease with cloths (E120). 9. Install adapter assembly (1) with retainer (16) on splines (3) of output shaft (2).  Then install retainer (19) and lockring (20).  (Task 6-9). 10. Install No.  7 drive shaft (3) (Task 6-19). INSPECT FOLLOW-ON MAINTENANCE: Close pylon lower fairing (Task 2-2). Close pylon hinged fairing (Task 2-2). Perform ground run (TM 1-1520-240-10). END OF TASK Change 1 6-63