  764    765    766    767    768  769  770    771    772    773    774  
TM  55-1520-240-23-4 5-137.1 REPAIR  COMPOSITE WEATHER-PROTECTIVE COVER  (AVIM) (Continued) 5-137.1 93. Remove  plug  (38)  from  cutout  (37).   Tape  an aluminum  plate  (E71) (40) against  cutout  on underside  of cover (1).  Use  nylon  tape  (E390.1). 94. Apply  nylon  tape  (E390.1) (41)  around  cutout (37) on  top  side  of  cover  (1).   Install  core  plug (38) in  cutout against  aluminum  plate  (40).  Sand plug  flush  with  tape.  Use  abrasive  paper (E6) and  sanding  block long  enough  to  span  plug. 95. Remove  tape  (41).  Matchmark  core  plug  (38) to cover  (1).   Remove  plug. 96. Go  to  step  99. 97. If  core  plug  (38) is  same  height  as  surrounding core  (39),  cut  two  pieces  of  fiberglass  laminate (E168.1) (42) to  fit  cutout (37)  at  top  and  bottom of  cover  (1). 98. Check  that  pieces  of  laminate  (E168.1)  (42) fit against installed  core  plug  (38)  flush  with  cover (1) on  both  sides.  Remove  laminate  and  plug. 5-769