TM 55-1520-240-23-3
4-154
REMOVE FADEC RELAY PANEL
4-154
INITIAL SETUP
Applicable Configurations:
With 74
Tools:
Electrical Repairers Tool Kit, NSN 5180-00-323-4915
Materials:
Paper Tags (E264)
Personnel Required:
Aircraft Electrician
References:
TM 55-1520-240-23P
Equipment Condition:
Battery Disconnected (Task 1-39)
Electrical Power Off
Hydraulic Power Off
1.
Remove screw (1) and washer (2) from clamp (3).
2.
Remove clamp (3) from wire bundle (4).
3.
Tag and disconnect six connectors (5) from
relays (6). Use tags (E264).
4.
Remove screws (7), washers (8), and spacers
(9) from relays (6).
5.
Remove relays (6) from FADEC relay panel (10).
6.
Remove screws (11) and washers (12) from
FADEC relay panel (10).
7.
Remove FADEC relay panel (10) from mounting
brackets (13).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
4-510