TM  55-1520-240-23-3
4-68.4
REPLACE  ENGINE  SCREEN BYPASS  PANEL FASTENERS
(Continued)
4-68.4
Epoxy  primer  (E292) is  flammable
and  toxic.   It  can  irritate  skin  and
cause  burns.  Use  only with  adequate
ventilation,  away  from  heat  or  open
flame.   Avoid  contact  with  skin,  eyes,
or  clothing.   In  case  of  contact,
immediately flush  skin  or eyes  with
water  for  at  least 15 minutes.   Get
medical  attention  for eyes.
NOTE
Procedure  is  similar  to  remove
Deutsch  fastener  from  any  screen.
Removal  from  lower bypass panel and
screen  is  shown.
REPLACE  STUD
1.
If  installed,  drill  rivets (1)  from  retainer  (2) and
panel  (3).
2.
Heat  retainer (2)  to  140ºF  to 160ºF (60ºC  to
71ºC) and  remove  from  panel  (3).   Use  heat
lamp.   Monitor  temperature  with  temperature
indicating  strips  (E413).
3.
Remove  retaining  ring  (4)  and  stud  (5)  from
panel  (3).
NO  BREAK  -  WORK  HARDER
NO  BREAK  -  WORK  HARDER
NO  BREAK  -  WORK  HARDER
Acetone (E20) is extremely flammable.
It  can  be  toxic.   Avoid  inhaling.   Use
only with  adequate  ventilation.  Avoid
contact  with  skin,  eyes,  or  clothing.
Keep  away from  heat, sparks,  or open
flame.  In  case  of  contact, immediately
flush  skin  or  eyes  with  water for
at  least  15  minutes.   Get  medical
attention  for  eyes.
4.
Remove  epoxy finish  from bonding  surface  (7) of
retainer  (2) and  panel  (3).   Use  acetone  (E20)
and  abrasive  pads  (E2).
5.
Clean  bonding  surfaces  (7)  on  new  retainer (2)
and  panel  (3).   Use  cloths  (E120)  and  solvent
(E161).
4-297