TM  55-1520-240-23-3 4-10 REMOVE  POWERPLANT (Continued) 4-10 6. Tag  and  disconnect  three  hoses  (15)  at transmission  (16).  Drain  oil  into  container.  Wipe up  any spilled  oil.  Use  cloths  (E135). 7. Disconnect  cable  plug  (17). 8. Remove  lockwire  from  two  bolts  (18)  on  two forward  engine  mount  caps (19).   Loosen  bolts and  push  down. 9. Install  sling  (20) as follows: a. Open  access  door  (21)  in  engine  access cover  (22). b. Connect  two  cables (23) to  forward  fittings (24) on  powerplant  (1). c. Connect  cable  (25) into  aft  fitting  (26) through cover  (22). d. Adjust sling  (20) until  eye  (27) is over  center hole  (28)  in  sling  bar  (29). e. Install  pin  (30)  through  bar (29). 4-48