TM 55-1520-240-23-10
15-5
INSPECT APU AFT MOUNTS
(Continued)
15-5
1.
Have helper push up on APU (1) under vertical
mount link (2) until all slack is taken up. Move
APU from side to side as far as it will go.
2.
Measure total travel of exhaust duct (3) in
exhaust closure (4). Total side to side or vertical
measurement shall not exceed 1/8 inch. If
measurement exceeds 1/8 inch, check vertical
mount link (2) and lateral mount link (5) for wear.
FOLLOW-ON MAINTENANCE:
None
END OF TASK
15-27