TM 55-1520-240-23-1
1-79
CLEAN AFTER SALT WATER LANDING OR IMMERSION
(Continued)
1-79
1.
Cover sideslip ports (1) on both sides of nose.
Cover static ports (2) on both sides of fuselage.
Use barrier material (E80) and masking tape
(E388).
2.
Rinse all areas exposed to salt water or spray.
Use fresh water.
3.
Open cargo ramp (3) halfway (TM
55-1520-240-T). Leave door (4) extended.
NO BREAK - WORK HARDER
NO BREAK - WORK HARDER
4.
Remove following cabin floor panels (Task
2-204):
Forward inboard (5)
Center outboard (6)
Aft inboard (7)
5.
Flush underfloor areas with fresh water.
6.
Flush between cargo ramp (3) and door (4) with
fresh water. Flush ramp hinge fittings (8).
1-299