1-78
CLEAN HYDRAULIC PISTONS
(Continued)
1-78
CLEAN RAMP ACTUATOR CYLINDER PISTONS
NOTE
Ramp must be lowered to expose full
length of piston.
13.
Lower cargo ramp (10) (TM 55-1520-240-T).
14.
Dip a clean cloth (E120) in hydraulic fluid (E197
or E199). Wipe pistons (11) with wet cloth to flush
away grit. Leave a thin film of fluid on pistons.
15.
Wipe up any spilled fluid.
16.
Raise cargo ramp (TM 55-1520-240-T).
NO BREAK - WORK HARDER
FOLLOW-ON MAINTENANCE:
None
END OF TASK