1-64 SERVICE UTILITY  SYSTEM  APU START ACCUMULATOR (Continued) - TM-55-1520-240-23-1_275
1-65 SERVICE UTILITY SYSTEM  APU  START MODULE ACCUMULATOR (Continued)

TM-55-1520-240-23-1 UH-1H/V and EH-1H Aircraft Manual
Page Navigation
  238    239    240    241    242  243  244    245    246    247    248  
TM  55-1520-240-23-1 1-65 SERVICE  UTILITY  SYSTEM  APU  START MODULE  ACCUMULATOR 1-65 INITIAL  SETUP Applicable Configurations: All Tools: Aircraft  Mechanic’s Tool  Kit, NSN 5180-00-323-4692 Source  of  High-Pressure  Compressed  Air or Nitrogen with  0-3000  Psi  Air  Gage  and  Pressure  Regulator Torque  Wrench,  30  to  150  Inch-Pounds Materials: Lockwire  (E231) Personnel  Required: Medium  Helicopter Repairer Inspector Equipment  Condition: Battery Disconnected  (Task  1-39) Electrical  Power Off Hydraulic  Power Off Emergency  Utility  Pressure  Valve  to  Open  (TM 55-1520-240-T) Cargo  Ramp  Open  and  Level (TM  55-1520-240-T) 1. Measure  and  record  outside  air  temperature. Use  fat  gage  (1)  in  cockpit. 2. Press  depressurization  valve  (2)  on  APU start  module  (3).   Hold  valve  until  sound  of depressurizing  has  stopped. 3. Read  accumulator  gage  (4). 1-249