TM  55-1520-240-23-1 1-65 SERVICE UTILITY  SYSTEM  APU START MODULE ACCUMULATOR (Continued) 1-65 11. Torque  nut  (8)  to  60  inch-pounds.   Install lockwire  (E231). 12. Install  cap  (5) on  valve  (6). INSPECT 13. Charge  accumulator  (9).  Use  hand  pump  (10). Read  pressure  on  accumulator gage  (11).   If temperature  is  above  -25ºF  (-32ºC),  charge accumulator  to  3000 psi.  If temperature  is  below -25ºF  (-32ºC),  charge  accumulator to 3350 psi  or  until  pointer of accumulator  gage  stops moving,  whichever occurs  first. FOLLOW-ON MAINTENANCE: Check utility hydraulic  reservoir level  (Task 1-62). END  OF  TASK 1-251