1-57 SERVICE VERTICAL HINGE PIN OIL TANKS    (Continued) - TM-55-1520-240-23-1_249
1-58 SERVICE ROTARY-WING  SHOCK  ABSORBER

TM-55-1520-240-23-1 UH-1H/V and EH-1H Aircraft Manual
Page Navigation
  212    213    214    215    216  217  218    219    220    221    222  
TM  55-1520-240-23-1 1-57 SERVICE  VERTICAL HINGE  PIN OIL  TANKS (Continued) 1-57 6. Lockwire  plugs  (3) to  sight  indicators  (2).   Use lockwire  (E231). INSPECT NO  BREAK  -  WORK  HARDER NO  BREAK  -  WORK  HARDER FOLLOW-ON MAINTENANCE: Close  work  platforms  (Task  2-2). Remove  tiedown  lines from  blades  (Task 1-26). END  OF  TASK 1-223