TM 55-1520-240-23-9
11-175
INSTALL LINEAR TRANSDUCER END FITTING BEARING (AVIM)
11-175
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Arbor Press
Adapters
Staking Tool, Circumferential Line Type
Materials:
Carbon Dioxide (Dry Ice) (E92)
Methanol (E243)
Epoxy Primer (E292)
Cloth (E120)
Gloves (E184.1)
Kevlar Gloves (E187)
Personnel Required:
Machinist
Inspector
References:
TM 55-1520-240-23P
TM 55-1500-322-24
General Safety Instructions:
Carbon dioxide (dry ice) (E92) is
toxic. It can irritate skin and cause
burns. Avoid inhaling. Use only with
adequate ventilation. Avoid contact
with skin, eyes, or clothing. In case
of contact, immediately flush skin
or eyes with water for at least 15
minutes. Get medical attention for
eyes.
Methanol (E243) is flammable and
toxic. Use only with adequate
ventilation. Keep away from heat and
open flame. Do not inhale. Do not
contact eyes, skin, or clothing. In
case of contact, immediately flush
skin or eyes with water for at least
15 minutes. Get medical attention
for eyes.
Carbon dioxide (dry ice) (E92) in
methanol (E243) has a temperature of
-120ºF (-84ºC). Employ all suitable
safety measures when working with
dry ice (E92) and methanol (E243),
and when handling chilled parts.
Avoid breathing carbon dioxide vapor.
Wear protective Kevlar gloves (E187)
when handling chilled bearing.
11-695