TM 55-1520-240-23-9
11-66
INSTALL THRUST CONTROL (PILOT)
(Continued)
11-66
Acetone (E20) can form toxic
vapors if exposed to flares. Use in
well-ventilated area, away from open
flame. In case of contact, immediately
flush skin or eyes with water for
at least 15 minutes. Get medical
attention for eyes.
12.
Clean old sealant from flange (28) of landing light
housing assembly (29). Use acetone (E20) and
cloths (E120). Clean old sealant from inside of
flange (30). Wear gloves (E186).
Sealant (E336) can irritate skin and
cause burns. Avoid contact with skin,
eyes, and clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
13.
Apply sealant (E336) to both sides of gasket
(31). Install gasket on flange (28). Wear gloves
(E186).
14.
Tilt housing assembly (29) to one side and guide
it up and inside structure (30). Make sure lamp
(32) is aft.
15.
Connect electrical lead (33) to stud (34). Install
washer (35) and nut (36).
11-302