TM 55-1520-240-23-911-41SWASHPLATE BALL AND SLIDER TRAVEL CHECK(Continued)11-413.Working from forward left work platform,measure and record distance between bottom ofswashplate ball slide (5) and stop (6) on sliderguide (7). Distance must not be less than 3/64inch. Use a feeler gage.4.Press switch (3) on stick (4). Position stick fullyaft. Do not move stick left or right. Releaseswitch.5.Working from aft left work platform, measure andrecord distance between bottom of swashplateball slider (8) and stop (9) on slider guide (10).Distance must not be less than 17/64 inch.11-158