206.
Set AFCS ANN switch (70) to ON. AFCS NO. 1
SYS caution light (71) shall be on.
207.
Set AFCS ANN switch (70) to OFF. AFCS NO. 1
SYS (without
74
or AFCS 1 (with
74
) caution
light (71) shall be off.
208.
Set DASH PRE-ENGAGE switch (72) to ON.
AFCS NO. 1 SYS (without
74
) or AFCS 1 (with
74
) caution light (71) shall be on.
209.
Set DASH PRE-ENGAGE switch (72) to OFF.
AFCS NO. 1 SYS caution light (71) shall be off.
210.
If no further testing is required, shut down
AFCS line test set 145G009-1. (Refer to TM
55-4920-429-13.)
END AFCS SELECT SIGNAL TEST (BOTH)
FOLLOW-ON MAINTENANCE:
Remove cockpit rigging tool (Task 11-23).
Install controls closet panel (Task 2-2).