TM 55-1520-240-23-9
11-280
AFCS INTERFACE TEST
(Continued)
11-280
TEST 28
BITE ENABLE TEST (BOTH)
172.
Set AFCS SYSTEM SEL switch (1) to 1 or 2.
(System under test.)
173.
Set METER SOURCE switch (3) to DISCRETE
MON.
174.
Set DISCRETE SIGNAL MONITOR switch (34)
to SEL 2.
175.
Set ENGINE CONDITION levers (61 and 62) to
STOP.
176.
Set SIGNAL SEL 2 switch (35) to BITE ENABLE
STOP. STATUS A light (37) shall come on.
177.
Move either ENGINE CONDITION lever (61 or
62) out of STOP. STATUS A light (37) shall go
out. STATUS B light (39) shall come on.
178.
Set ENGINE CONDITION lever (61 or 62) to
STOP.
END BITE ENABLE TEST (BOTH)