BENCH TEST AFCS COMPUTER (AVIM)
(Continued)
11-277
TEST 12
PRESSURE TRANSDUCERS TEST
NOTE
Perform preliminary procedure before
test. (Refer to TM 55-4920-430-13.)
732.
Set METER switch (6) to DC.
733.
Set NORM ACCEL J2-52 switch (65) to GND.
734.
Set METER RANGE switch (7) to 2V.
735.
Set CIRCUIT SELECT TENS switch (8) to 30.
736.
Set CIRCUIT SELECT A UNITS switch (18) to 7.
737.
Set CIRCUIT SELECT A/B SELECT switch (9) to
A. Read and record V1 AC/DC VOLTMETER (10)
reading. Reading shall be be -0.030 to +0.030.
738.
Remove cap (73) from fitting (74) on back of
tester (75).
739.
Connect hose (76) (APP E-36) to fitting (74) and
port L (77) on computer (69).
740.
Connect cable (78) to receptacle (79) and 115
volt 60 Hz bench power supply.