TM 55-1520-240-23-8
10-17
TESTING REPAIRED CELL SOAP SUDS
10-17
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Overhead Suspension for Fuel Cell (APP E-16)
Tee Fitting
Manometer
Source of Low Pressure Dry Air
Open Container, 5 Gallon
Materials:
Brush (E85)
Soap (E353)
Personnel Required:
Medium Helicopter Repairer
Inspector
References:
Task 10-2
Task 10-3
Task 10-11
Task 10-12
Task 10-15
Equipment Condition:
Off Helicopter Task
General Safety Instructions:
Test pressure within the fuel cell shall
not exceed 1.5 psi. Damage to the
cell could result in personal injury or
death.
10-68