TM 55-1520-240-23-8
10-99
REMOVE APU FUEL SOLENOID VALVE
(Continued)
10-99
1.
Place container under pump (1) to catch spilled
fuel.
2.
Disconnect electrical connector (2).
3.
Remove lockwire and disconnect electrical
connector (3).
4.
Disconnect fuel hose (4). Plug hose connector.
Cap nipple (5) in pump (1).
5.
Disconnect fuel hose (6). Plug hose connector.
6.
Disconnect drain hose (7). Plug hose connector.
Cap elbow (8).
7.
Remove four screws (9) and four washers (10).
Disconnect electrical lead (11).
8.
Remove pump (1) and solenoid valve (12).
9.
Wipe up spilled fuel. Use cloths (E135).
10.
Loosen locknut (13).
11.
Hold nipple (14) with wrench. Use wrench on
flats of valve (12). Remove valve, packing (15)
and locknut (13).
12.
Plug port in valve (12) and cap nipple (14).
13.
Remove nipple (16) and packing (17). Plug port
in valve (12).
14.
Remove screw (18), washer (19) and electrical
lead (11).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
10-462