TM 55-1520-240-23-8
10-92
INSTALL NO. 2 SYSTEM (RIGHT SIDE) MAIN FUEL TANK SERVICING CHECK VALVE
10-92
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Strap Wrench
Materials:
Lockwire (E233)
Dry Cleaning Solvent (E162)
Gloves (E186)
Cloths (E135)
Parts:
Packings
Gaskets
Personnel Required:
Medium Helicopter
Inspector
References:
TM 55-1520-240-23P
General Safety Instructions:
All regulations and instructions
for handling fuels shall be strictly
observed.
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
10-441