TM 55-1520-240-23-8
10-80
INSTALL AFT FUEL TANK BOOST PUMP
(Continued)
10-80
INSTALL ACCESS DOOR
7.
Position gasket (19) and access door (20) next to
access hole (1). Insert electrical receptacle (21)
through hole (22) in door. Check that packing is
installed on receptacle. Install keywasher (23.1).
Install and hand tighten locknut (23) on electrical
receptacle. Remove tag from cable (24).
8.
Insert electrical receptacle (25) through hole (26)
in door (20). Check that packing is installed on
receptacle. Install and hand tighten locknut (27)
on electrical receptacle. Remove tag from cable
(28).
9.
Insert electrical receptacle (29) through hole (30)
in door (20). Install and hand tighten locknut
(31) on electrical receptacle. Remove tag from
cable (32).
10.
Remove plug from hose (33) and cap from
adapter (34) on inside of door (20). Connect
hose to adapter.
11.
Position gasket (19) and access door (20)
against face of tank (2). Position lanyard release
cable (35) as shown. Install 30 bolts (36) and
washers (37). Torque bolts to 70 inch-pounds.
12.
Tighten three locknuts (23, 27, and 31). Bend
tabs on keywasher (23.1).
10-379