TM 55-1520-240-23-7
9-149
ASSEMBLE EMERGENCY HOOK RELEASE RELAY BOX (AVIM)
(Continued)
9-149
12.
Position relay (27) in box (7).
13.
Install harness (9) and relay (27).
14.
Install four screws (28) and washers (29).
15.
Connect 22 wires (30) on terminals (31). Remove
tags.
16.
Connect diode (32). Install 12 washers (33) and
nuts (34).
17.
Cement diode (32) to relay (27). Use protective
coating (E305).
18.
Install relay (33), two washers (34), and screws
(35).
19.
Install insulation sleeving (36) on wires (37). Use
insulation sleeving (E204).
20.
Solder six wires (37) to terminals (38). Use
solder (E360). Remove tags.
21.
Position insulation sleeving (36) against relay.
Shrink sleeving with heat gun.
22.
Position relay (39). Install two screws (40),
washers (41), and nuts (42).
23.
Install insulation sleeving (43) on five wires (44).
Use insulation sleeving (E204).
24.
Solder five wires (44) to terminals (45). Use
solder (E360).
25.
Position sleeving (43) against relay (39). Shrink
sleeving with heat gun.
26.
Position relay (46) on box (7). Install two screws
(47), washers (48), and nuts (49).
27.
Install insulation sleeving (50) on five wires (51).
Use insulation sleeving (E204).
28.
Solder wires (51) to terminals (52). Use solder
(E360).
29.
Position sleeving (50) against relay (46). Shrink
sleeving with heat gun.
INSPECT
9-605