TM 55-1520-240-23-7
9-91
INSTALL ANTICOLLISION LIGHT
(Continued)
9-91
Acetone (E20) can form toxic
vapors if exposed to flame. Use in
well-ventilated area, away from open
flame. In case of contact, immediately
flush skin or eyes with water for
at least 15 minutes. Get medical
attention for eyes.
3.
For either light (1), clean old sealant (5) from
fuselage (6). Use acetone (E20) and cloths
(E120). Wear gloves (E 186).
3.1.
On bottom light only, install two pieces of shrink
tubing (7).
4.
Support light (1). Connect connector (8) to light.
Lockwire (E231) connector to light.
5.
Position light (1) on fuselage (6).
6.
Install 18 screws (9) and washers (10).
Sealant (E336) can irritate skin and
cause burns. Avoid contact with skin,
eyes, and clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
7.
Seal 18 screws (9) and edge of light (1). Remove
decals and seal three drain holes (11). Use
sealant (E336). Wear gloves (E186).
INSPECT
FOLLOW-ON MAINTENANCE:
Perform operational check (TM 55-1520-240-T).
END OF TASK
9-299