TM 55-1520-240-23-7
8-73
TEST TRANSMISSION OIL TEMPERATURE SELECTOR SWITCH OR INDICATOR
(AVIM)
(Continued)
8-73
NOTE
For testing indicator, a known good
selector switch is used.
For testing selector switch a known
good indicator is used.
Perform steps 1 thru 52 if testing
selector switch.
Perform steps 8 thru 52 if testing
indicator.
SELECTOR SWITCH CONTINUITY AND RESISTANCE
TEST
1.
Connect multimeter (1), set to RX1, to pins A and
L of selector switch (2).
2.
Rotate selector switch knob (3) through all dial
positions. Check multimeter (1). Multimeter
shall indicate continuity at all switch positions.
Disconnect multimeter.
3.
Connect multimeter (1), set to RX1, to pins A
and D of selector switch (2). Repeat step 2.
Disconnect multimeter.
4.
Connect multimeter (1) set to RX1 to pin A and
case ground (4) (receptacle shell). Repeat step
2. Disconnect multimeter.
5.
Set selector switch knob (3) to SCAN.
6.
Connect multimeter (1), set to RX 10,000 to
pins N to S of switch (2). Check multimeter (1).
Multimeter shall indicate between 9.975 and
11.025 K ohm.
7.
Repeat step 6 between pins N to R, N to G, N to
H, and N to F of switch (2). Then go to step 8.
8-197