TM 55-1520-240-23-6
7-13
FLUSHING FLIGHT CONTROL HYDRAULIC SYSTEM (RETURN LINES)
7-13
INITIAL SETUP
Applicable Configurations:
All
Tools:
Hydraulics Repairers Tool Kit, NSN
5180-00-323-4891
Container
Hydraulic Test Stand
Filter Assembly Kit ADHT6814-M9716M
Materials:
Hydraulic Fluid (E199)
Cloths (E120)
Gloves (E186)
Parts:
Hoses
Personnel Required:
Aircraft Pneudraulics Repairer
Inspector
Equipment Condition:
Flight Control System Prepared for Flushing (Task
7-12)
General Safety Instructions:
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
Hydraulic fluid ejected under pressure
can cause injury to personnel.
Hydraulic fluid sprayed into the air is
a fire hazard.
7-81