INSTALL WINCH MOTOR
(Continued)
7-248
4.
Position motor (2) on flange (1) as shown. Install
four bolts (4), eight washers (5), and four nuts (6).
5.
Install washers (7) and packings (8) on three
elbows (9).
6.
Install three elbows (9). Do not tighten nuts (10)
at this time.
7.
Connect three hoses (11). Remove tags.
8.
Tighten nuts (10).
INSPECT
FOLLOW-ON MAINTENANCE:
Bleed utility hydraulic winch system (Task 7-333).
Check operation of winch motor (TM 55-1520-240-T).
Install heater compartment acoustic blanket (Task
2-210).
END OF TASK