TM 55-1520-240-23-6
7-198
REMOVE UTILITY RETURN CONTROL MODULE FILTER INDICATOR
(Continued)
7-198
1.
Disconnect connector (1) from indicator (2). Use
gloves (E186).
2.
Remove lockwire from four screws (3).
3.
Remove four screws (3) from indicator (2).
4.
Remove indicator (2), two retainers (4), and
packing (5).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-780