TM 55-1520-240-23-6
7-181
REMOVE APU START SOLENOID PILOT VALVE
(Continued)
7-181
1.
Disconnect connector (1) from valve (2).
2.
Remove lockwire from valve (2). Remove valve,
three packings (3) and six retainers (4) from
START PLT V port (5). Use container and cloths
(E135) for spilled fluid. Use gloves (E186).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-747