TM 55-1520-240-23-6
7-178
INSTALL APU START MODULE ACCUMULATOR
(Continued)
7-178
3.
Install valve and gage (5) and two packings (6) in
accumulator (1).
4.
Tighten nut (7) against accumulator (1).
5.
Lockwire valve and gage (5) and accumulator
(1). Use lockwire (E231).
NO BREAK - WORK HARDER
NO BREAK - WORK HARDER
INSPECT
FOLLOW-ON MAINTENANCE:
Service APU accumulator (Task 1-65).
Bleed utility hydraulic system (Task 7-336).
Perform operational check (TM 55-1520-240-T).
Close cargo ramp (TM 55-1520-240-T).
END OF TASK
7-741