TM 55-1520-240-23-6
7-147
INSTALL APU MOTOR PUMP
(Continued)
7-147
Do not install motor pump with dry
case. This will cause internal damage
to pump.
2.
Fill case of motor pump (1) through case drain
port (4) with clean hydraulic fluid (E199).
3.
Install cap (3) on fitting (5). Use cloths (E135)
for spilled fluid.
4.
Remove barrier material and coat splines (6)
with grease (E190).
4.1.
Install gasket (7).
7-650