TM 55-1520-240-23-6
7-140.2
DISASSEMBLE HANDPUMP HANDLE
(Continued)
7-140.2
4.
Remove 3/32 inch cap screw (7).
5.
Slide outer-tube (5), until button (3) is exposed
(pops up).
6.
Depress button (3), compressing spring (8), so
that button (3) is below hole in retainer (9).
7.
Rotate retainer (9) to keep button (3) from
popping up.
8.
Slide outer-tube (5) down exposing top of retainer
(9).
Depressed spring may pop out
causing injury.
9.
Carefully slide retainer (9) out cap end (10) of
handle (2).
10.
Remove spring (8) and button (3).
11.
Remove outer tube (4) from inner tube (5).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-632