TM 55-1520-240-23-6
7-98
TEST PITCH, ROLL, YAW, OR THRUST INTEGRATED LOWER CONTROL ACTUATOR
(ILCA) (AVIM) (Continued)
7-98
284.
Install cap (89) on adapter (87). Remove adapter
and stow. Use cloths (E135) for spilled fluid.
Wear gloves (E184.1).
285.
Remove PIN 2 (69) from input arm (61).
286.
If relief valve testing is not required, perform the
following:
a.
Install valve (90) and packing (91) in port (92).
b.
Torque valve (90) to 17 inch-pounds.
c.
Apply a bead of sealant (E336) around
perimeter of valve (85) and valve (90). Wear
gloves (E184.1).
NOTE
Valve (85) and valve (90) are removed
in Test 16, Relief Valve Test (ALL).
d.
Lockwire valve (85) and valve (90). Use
lockwire (E231).
287.
If no further testing is required, perform normal
shutdown (TM 55-4920-248-13).
INSPECT
END CASE CAVITY LEAK TEST
7-460
Change 1