TM 55-1520-240-23-6
7-98
TEST PITCH, ROLL, YAW, OR THRUST INTEGRATED LOWER CONTROL ACTUATOR
(ILCA) (AVIM) (Continued)
7-98
165.
Set SAS PRESS SYS 1 valve (3) to OFF. Read
and record cross feedback reading on DVM (58).
Compare reading with null reading from step 55.
The difference shall be 0.065 or less.
166.
Set SAS PRESS SYS 1 valve (3) to PRESS.
167.
Set SAS PRESS SYS 1 valve (3) to OFF. Read
and record cross feedback reading on DVM (58).
Compare reading with null reading from step 55.
The difference shall be 0.065 or less.
168.
Set SAS PRESS SYS 1 valve (3) to PRESS.
169.
Set SAS PRESS SYS 1 valve (3) to OFF. Read
and record cross feedback reading on DVM (58).
Compare reading with null reading from step 55.
The difference shall be 0.065 or less.
169.1. Set SAS PRESS SYS 1 valve (3) to PRESS.
169.2. Set SAS PRESS SYS 1 valve (3) to OFF. Read
and record cross feedback reading on DVM (58).
Compare reading with null reading from step 55.
The difference shall be 0.065 or less.
NOTE
If voltage reading is not within limits,
replace extensible link.
170.
Set SAS 1 VALVE CONTROL (34) to NULL.
171.
Set SAS PRESS SYS 1 valve (3) to VENT then
OFF.
7-444
Change 1