TM 55-1520-240-23-6
7-98
TEST PITCH, ROLL, YAW, OR THRUST INTEGRATED LOWER CONTROL ACTUATOR
(ILCA) (AVIM) (Continued)
7-98
f.
Set SYSTEM SELECT switch (43) to SAS 2.
g.
Set SAS 2 LINK TEST switch (39) to CROSS
FDBK.
h.
Record reading indicated on DVM (58).
i.
Record reading indicated on indicator (9).
j.
Set SAS 1 FUNCTION SELECT switch
(30) to HARDOVER RETRACT. Set SAS
2 FUNCTION SELECT switch (31) to
HARDOVER EXTEND.
k.
Record reading indicated on DVM (58).
l.
Set SYSTEM SELECT switch (43) to SAS 1.
m.
Set SAS 2 FEEDBACK SELECT switch (33)
to CROSS.
n.
Record reading indicated on DVM (58).
o.
Record reading indicated on indicator (9).
p.
Check readings from steps i and o. The
difference between the readings shall be 1.24
to 1.48 inches.
q.
Check readings from steps e, h, k, and n.
Readings shall be 1.50 to 1.91 volts.
Change 1
7-435