TM 55-1520-240-23-6
7-338
BLEEDING UTILITY HYDRAULIC SYSTEM ENGINE START SYSTEMS
7-338
INITIAL SETUP
Applicable Configurations:
Without 74
Tools:
Hydraulic Repairers Tool Kit, NSN 5780-00-323-4891
Hydraulic Test Stand
Filter Assembly Kit ADHT 6814-M9716M
Container
Reducers, MS21916012-10
Materials:
Cloths (E120)
Gloves (E184.1)
Personnel Required:
Aircraft Pneudraulics Repairer
Inspector
Equipment Condition:
Battery Connected (Task 1-39)
Electrical Power On
Hydraulic Power Off
Hydraulic Connection Access Panel Open (Task 2-2)
Engine Access Covers Open (Task 4-49)
General Safety Instructions:
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
Hydraulic fluid elected under pressure
can cause injury to personnel.
Hydraulic fluid sprayed into the air is
a fire hazard.
7-1244