TM 55-1520-240-23-6
7-328
FLUSH APU AND AFT TRANSMISSION PUMP CASE DRAINS
(Continued)
7-328
14.
Disconnect hose (4) from ports (5 and 6) of
module (2).
15.
Connect tube (3) to APU CD port (6) of module
(2).
16.
Connect tube (1) to UTIL PMP CD port (5) of
module (2).
INSPECT
FOLLOW-ON MAINTENANCE:
Install APU drip pan (Task 2-3).
Close ramp (TM 55-1520-240-T).
Close aft transmission baffles (Task 2-2).
END OF TASK
7-1205