TM 55-1520-240-23-6
7-316
FLUSH ENGINE START RETURN TUBING
7-316
INITIAL SETUP
Applicable Configurations:
All
Tools:
Hydraulic Repairers Tool Kit, NSN 5180-00-323-4891
Hoses
Test Stand
Container, 2 Quart
Materials:
Cloths (E135)
Gloves (E184.1)
Personnel Required:
Aircraft Pneudraulics Repairer (2)
Inspector
Equipment Condition:
Battery Disconnected (Task 1-39)
Electrical Power Off
Hydraulic Power Off
Utility Hydraulic System Depressurized (Task 7-135.1)
Cargo Ramp Open and Level (TM 55-1520-240-T)
Right and Left Engine Lower Access Covers Open
(Task 4-49)
General Safety Instructions:
Hydraulic fluid (E199) is toxic. It can
irritate skin and cause burns. Avoid
inhaling. Use only with adequate
ventilation. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
Hydraulic fluid ejected under pressure
can cause injury to personnel.
Hydraulic fluid sprayed into the air is
a fire hazard.
7-1132